Two-end open/closed type, two-end open type, single-loop open/closed type.
Two-end open/closed type:
When not connected: When the female body's collar moves to the other end, the stainless steel ball automatically rolls outward. The male body disconnects due to the combined valve spring force of the female and male bodies, and the valves of the female and male bodies close instantly, instantly blocking fluid flow.
When connected: When the male body is inserted into the female body, the collar returns to its original position under the action of the spring. The rolling steel ball locks the male body tightly. Simultaneously, the valves of the female and male bodies push each other open, allowing fluid to flow. The O-ring completely prevents fluid leakage.
Two-end open type:
When not connected: When the female body's collar is pushed to the other end, the steel ball automatically rolls outward, thus removing the male body. Since neither the male nor female body has valves, fluid flows outward.
When connected: When the male body is inserted into the female body, the collar is pushed back to its previous position by the force of its spring, locking the steel ball and allowing fluid to flow. The O-ring prevents leakage.
Single-circuit opening/closing:
Without connection: When the female body's collar moves to the other end, the stainless steel ball automatically rolls outward, and the male body is pushed open by the valve spring's reaction force, automatically closing the valve to stop fluid flow.
With connection: When the male body is inserted into the female body with the collar, the valve opens, allowing fluid flow. The gasket is pushed back to its original position by the spring force, and the stainless steel ball locks in place to ensure the male/female connection. The inner gasket completely prevents fluid leakage.